Group • tcl – i
Your strong, reliable Partner in
Building Condition Analysis,
Documentation
and.....
|

|
|
tcl - i • CRACKMONITOR©
Measuring Devices for monitoring movement in cracks in Buildings
tcl - i • OPTOMETRICS DERMAPHOT
the System fordocumentative Macro-Photography, simple as taking snapshots, only much better
tcl - i • OPTOMETRICS ENDOSCOPES
High poweredEndoscopeswith high resolution
tcl - i • OPTOMETRICS ILLUMINATED MAGNIFYERS
for inspection and dimensioning of defects and imperfections and Crack Depths
tcl - i •OPTOMETRICS ILLUMINATING and MIRROR PROBES
for inspection of difficult to reach nooks and crannies
|
|
Information & Service Centre A/CH/CZ/D/H/PL/SLO/SK/TR
Gruppe • tcl - i
Neuduerrlas 15 ● D-95199 THIERSTEIN
Tel.: +49 (0)9235 968885 • Fax: +49 (0)9235 968887
e-mail:info@rissmonitor.com· www.rissmonitor.com
|
|
tcl - i • OPTOMETRICS
|

|
Group • tcl - i
|
|
tcl - i • OPTOMETRICS DERMAPHOT
special Macro Lens for documentation of conditions and defects, excellently suited for use in the field and in laboratories. Distortion free imaging, highest resolution and trueness of colours, as well as simplest operation were the main criteria in developing this lens. Weight incl. batteriesonly 900 g.
|

|
|
FIX-FOCUS
the DERMAPHOT is being placed squarely upon the surface to be photographed, this ensures the object to be in focus.
INTEGRATED POSITIONING LIGHT
for clear visibility of the object section selected
INTEGRATED ELECTRONIC FLASH
ensures correct exposure every time
|

|
|
INTEGRATED MEASURING-SCALE
in the object plane, with 0.1 mm divisions provides parrallax free, inarguable dimensioning for accurate documentation. The Measuring Plate is interchangeable
|

|
|
tcl - i • OPTOMETRICS DERMAPHOT can be supplied for all common SLRs in 35 mm format with interchangeable lenses and is also suited for digital photography.
The tcl - i • OPTOMETRICS DERMAPHOT requires neither complicated and time consuming adjustments at lens and camera, nor „test“ exposures. The use of a tripod, as is required with most conventional macro photography, is here redundant. It facilitates high quality macro photography even by novices !
|

|
|

|
|
Fillet Weld macro etching documented with tcl – i● OPTOMETRICS DERMAPHOT
Film: Fujicolor CN 100 ASA, exposure: 1/125
|
|

|
|
Crack Width 0.2 mm documented with tcl – i● OPTOMETRICS DERMAPHOT
Film: Fujicolor CN 100 ASA, exposure: 1/125
|
|
Image Magnification:
|
approx. 2,5 x on 24 x 36mm Film (Negative or Slide)
approx. 10,6 x on 9 x 13 cm Print
approx. 25 x on 20 x 30 cm Print
|
|
|
|
|
|
tcl - i • OPTOMETRICS INSPECTION EQUIPMENT FOR EXPERTS
|
|
|
|
Special-Angled-Endoscope
|

|
|
Locating and determinig damages in enclosed spaces:
Buildings: Examination of masonry, ceiling voids, ducts, formwork,bearings, joints etc.,
Engineering: Gear boxes, turbines, engines, bearings etc.
Diameter required for inspection access: 10 mm, working depth of Endoscope: 320 mm, direction of view: 90º, optical angle: 35º. Battery operated, therefore mains independent. Fully charged battery affords 4,5 hours of operation. High powered Halogen lamp, range of illumination: approx. 600 mm, brightness infinitely variable. High resolution optical system.
|

|
|
For photographic documentation, the endoscope can be fitted to a SLR camera by means of a Photo Adaptor. The photo adaptor screws into the filter thread of the camera lens and fits over the ocular of the endoscope by a ball connector. Lens requirements: tele lens with min. 100 mm optical length. Due to the high loss of light, zoom lenses are not suitable for endophotography !
|

|
|
The Hard Shell Case –Inspection Set 1- contains 1 Endoscope complete with rechargeable battery box and charger, one 10x illuminating magnifyer, one 10x borescope, one illuminating probe 450 mm, 1 Inspection mirror Ø30 and the battery container handle.
The following optional extras are recommended:
Extension lead for more comfortable operation for magnifyer and borescope, prismatic telescope 3,5 – 5x for use with illuminating probe extension (to 1000 mm max.), and the Photoadaptor for endo photography.
Endoscopes available:
Rigid Endoscopes
from Ø 4,5 mm, working depths 140 mm
up to Ø 8 mm, working depths 490 mm
Flexible Endoscopes
From Ø 6 mm, working depths 1000 mm
Up to Ø 8 mm, working depths 2000 mm
|

|
|
10-x illuminating magnifyer with Measuring Plate
|
|
|
Examination of surfaces, infestations, contaminations, damages etc. Infinitely variable illumination, focusable, sharp distortion free image. Measuring plate with 1/10 mm divisions, high power Halogen lamp.

|


|
|
Borescope
|
|
|
For examination of hairline cracks, crack flanks, layer composition in concrete, masonry, timber and other materials. Determination of crack depth up to 250 mm, from crack width 0.3 mm – extension lead optional

|

|
|
Illuminating Probe 400 mm with Probe Head and inspection mirror Ø 30 mm
|
|
|
To provide additional lighting when endoscopically inspecting larger voids. Combined with the mirror for inspection of difficult to acces nooks and crannies. Extendable up to 1000 mm.

|

|
|

|
Optional extra:
3,5 to 5x prismatic telescope
|
|
|
|
SEMI FLEXIBLE FS 6/SFM 8 ENDOSCOPES
Working Depth 1000 mm and 2000 mm, Diameter 6 and 8 mm
|
|
|
|
|
|
|
|
- Semi flexible goose neck probe with light and image conductors, free manipulation
- Mains independent
- Ocularfocusable
- Probe water tight, low friction coating, robust, shock absorbing
|
- High Power Xenon-Halogen-Illumination, infinitely variable brightness
- SF 6 - 1000/SFM 8 -1000/2000 Set complete incl. 3,5/12 V Xenon-Halogen Spare Bulb, in Hard Shell Case
|
|

|

SF 6 ENDOSCOPE ready to use
|
|

|
|
SF 6 ENDOSCOPE with Photo Adaptor for photographic Documentation
|
|
TECHNICAL DATA:
|
|
|
WorkingDepth:
|
1000 or 2000 mm respectively
|
|
Diameter of Probe:
|
6 and 8 mm respectively
|
|
Illumination:
|
Integrated Cold Light Source, Xenon-Halogen Lamp 3,5 V/12 V provides up to 120,000 lx at viewing distance 16 mm
|
|
Power Source:
|
a) Battery Handle for 3 Alcaline-Manganese- Batteries LR14 for 10 hours working time
b) 12 V AccuBox for 2 hours working time per charge
|
|
Connection Battery Handle to Instrument:
|
Patented Quick Release Connector
|
|
Probe Coating:
|
Water, Oil and Petol resistant
|
|
Direction of View:
|
0°, side view adaptors 90° and 110° available as optional extra
|
|
Optical Angle:
|
50°
|
|
Viewing Distance:
|
from 10 mm to infinity
|
|
WasterResistance:
|
Lens and flexible Probe are Water Tight, no mist achromatic lens
|
|
Ocular:
|
Focusable
|
|
Resolution:
|
7,400 Pixel
|
|
Bending Radius of Probe:
|
30 mm min.
|
|
Permissible Ambient Temperature:
|
-20° to +60° C
|
|
Weight:
|
Incl. Case and Batteries 1400/1600 g
|
A range of accessories is available
|

|

|
|
Crack WidthDocumentationwith
tcl - i • OPTOMETRICS DERMAPHOT
|
Endoscopic Photography of crack and reinforcement layer in reinforced wall plaster with tcl - i • OPTOMETRICS rigid Endoscope
Nikkor 180 f 1:2,8 Fujicolor CN 100 ASA, 1/30 sec.
|
|